In this section, an optimization of the future system is to be performed through the following steps:
•Extending the existing system
•Grouping of pipes and assignment of cost data
•Defining candidate sizes for groups
•Defining the design loads/outputs
•Optimization settings and saving data
•Interpreting optimization results
Design Criteria:
For this exercise, PHF demand with minimum pressure requirement of 20 m throughout the system is defined as the first load case. The second load case is defined as the FIRE scenario, with 15 m throughout the system.
Both load cases will be considered while the pump is running, and the level in Tank 8 is 5 m.
At this stage, no consideration of pump cost, or tank cost, will be made. Only pipe sizing is evaluated.